The Amatrol 950-STCL1 is a comprehensive training system that brings the principles of closed-loop solar thermal technology into the classroom. It is specifically designed for technical students and aspiring technicians who need to develop practical, hands-on troubleshooting skills. The system provides a fully operational solar water heating circuit, complete with a solar collector, heat exchanger, and differential controller, allowing learners to bridge the gap between theory and real-world application. Its primary benefit is its ability to simulate common system faults in a safe, controlled environment. This enables students to practice diagnosing and resolving issues they will encounter in the field, such as pump failures, sensor errors, and flow problems. The 950-STCL1 equips future HVAC and renewable energy professionals with the essential competencies needed for installation, maintenance, and repair of modern solar thermal systems, making it an invaluable tool for vocational schools and technical colleges.
The 950-STCL1 training system is engineered to build tangible, job-ready skills. Students interact with industrial-grade components to master the operational sequence of a glycol-based solar heating system, from startup to shutdown. The curriculum focuses on systematic troubleshooting, teaching learners to interpret data from pressure gauges, flow meters, and temperature sensors to accurately diagnose system performance. Key applications include identifying and resolving electrical faults in the control unit, troubleshooting mechanical issues like a malfunctioning circulator pump, and correcting sensor inaccuracies. Learners will also practice addressing common hydraulic problems such as airlocks or flow obstructions. This practical experience ensures students are not just familiar with the components but are fully prepared to service and maintain residential and commercial solar thermal systems effectively.
| Specification / Feature | Description |
|---|---|
| Product Dimensions | 72 in. L x 36 in. W x 78 in. H |
| Product Weight | Approximately 450 lbs |
| Applicable Education Levels | Post-Secondary, Vocational, Adult Education |
| Integrated Fault Insertion System | Allows instructors to simulate over 20 real-world electrical and mechanical faults. |
| Solar Thermal Collector | Full-size flat plate collector with tempered glass glazing. |
| Solar Collector Lamp | Provides a controlled heat source for indoor operation. |
| Glycol/Water Heat Transfer Loop | Closed-loop circuit using a propylene glycol solution for heat transfer. |
| Differential Temperature Controller | Industrial-grade controller for managing system operation based on temperature inputs. |
| Pump Station | Pre-plumbed unit with circulator pumps, flow meter, and pressure relief valve. |
| Brazed Plate Heat Exchanger | Efficiently transfers heat from the collector loop to the storage tank loop. |
| Expansion Tank | Absorbs pressure fluctuations in the closed-loop circuit. |
| Storage Tank | Insulated tank for storing heated water. |
| Instrumentation | Includes multiple pressure gauges, temperature sensors, and flow meters. |
| Student Curriculum | Interactive, multimedia-based student learning materials. |
| Instructor’s Guide | Comprehensive guide with setup instructions, lesson plans, and fault scenarios. |
| Mobile Design | Mounted on a heavy-duty welded steel frame with casters for mobility. |
| Power Requirements | 120VAC / 60Hz / 1 Phase |
Aidex is proud to supply the Closed-Loop Solar Thermal Troubleshooting Training 950-STCL1 to learning institutions across the Midwest. We are committed to equipping educators and students in the region with the industry-leading tools they need to succeed in the growing field of renewable energy.
The curriculum covers a wide range of essential topics, including system operation and startup procedures, component identification and function, performance analysis, troubleshooting controller and electrical faults, diagnosing pump and flow issues, and resolving sensor errors and inaccuracies.
The primary audience includes students in HVACR, renewable energy technology, and industrial maintenance programs. It is ideal for use at community colleges, vocational schools, and technical training centers preparing the next generation of technicians.
Yes, it includes a comprehensive fault insertion system. This allows instructors to introduce common real-world problems for students to diagnose in a controlled setting, such as sensor failures, pump malfunctions, and controller errors.
Yes, the 950-STCL1 system comes with a detailed student curriculum delivered in an interactive multimedia format. A comprehensive instructor’s guide is also included to facilitate lesson planning and hands-on lab exercises.
The system requires a standard 120VAC/60Hz electrical connection and a water supply for the heat exchanger loop. A heat source, such as the included solar collector lamp, is also necessary for full operational training.
{
“@context”: “https://schema.org”,
“@graph”: [
{
“@type”: “Organization”,
“@id”: “https://www.aidex.com/#organization”,
“name”: “Aidex”,
“url”: “https://www.aidex.com/”,
“logo”: “https://www.aidex.com/wp-content/uploads/2020/10/Aidex-Logo-2020-Header-1.png”
},
{
“@type”: “WebSite”,
“@id”: “https://www.aidex.com/#website”,
“url”: “https://www.aidex.com/”,
“name”: “Aidex”,
“publisher”: {
“@id”: “https://www.aidex.com/#organization”
}
},
{
“@type”: “WebPage”,
“@id”: “https://www.aidex.com/product/amatrol-950-stcl1/#webpage”,
“url”: “https://www.aidex.com/product/amatrol-950-stcl1/”,
“name”: “Closed-Loop Solar Thermal Troubleshooting Training 950-STCL1 | Amatrol | Aidex”,
“isPartOf”: {
“@id”: “https://www.aidex.com/#website”
},
“datePublished”: “2023-10-26T10:00:00-05:00”,
“dateModified”: “2023-10-26T10:00:00-05:00”,
“description”: “Explore Amatrol’s 950-STCL1 for hands-on solar thermal troubleshooting training. Designed for educators and students, this system teaches critical skills. Available from Aidex. Request a quote today!”
},
{
“@type”: “Article”,
“@id”: “https://www.aidex.com/product/amatrol-950-stcl1/#article”,
“isPartOf”: {
“@id”: “https://www.aidex.com/product/amatrol-950-stcl1/#webpage”
},
“author”: {
“@id”: “https://www.aidex.com/#organization”
},
“publisher”: {
“@id”: “https://www.aidex.com/#organization”
},
“headline”: “Closed-Loop Solar Thermal Troubleshooting Training 950-STCL1 | Amatrol | Aidex”,
“datePublished”: “2023-10-26T10:00:00-05:00”,
“dateModified”: “2023-10-26T10:00:00-05:00”,
“mainEntityOfPage”: {
“@id”: “https://www.aidex.com/product/amatrol-950-stcl1/#webpage”
},
“wordCount”: 412,
“articleBody”: “The Amatrol 950-STCL1 is a comprehensive training system that brings the principles of closed-loop solar thermal technology into the classroom. It is specifically designed for technical students and aspiring technicians who need to develop practical, hands-on troubleshooting skills. The 950-STCL1 training system is engineered to build tangible, job-ready skills. Students interact with industrial-grade components to master the operational sequence of a glycol-based solar heating system, from startup to shutdown. The curriculum focuses on systematic troubleshooting, teaching learners to interpret data from pressure gauges, flow meters, and temperature sensors to accurately diagnose system performance.”
}
]
}
{
“@context”: “https://schema.org”,
“@type”: “FAQPage”,
“mainEntity”: [
{
“@type”: “Question”,
“name”: “What core topics does the Closed-Loop Solar Thermal Troubleshooting Training 950-STCL1 Curriculum Cover?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “
The curriculum covers a wide range of essential topics, including system operation and startup procedures, component identification and function, performance analysis, troubleshooting controller and electrical faults, diagnosing pump and flow issues, and resolving sensor errors and inaccuracies.
”
}
},
{
“@type”: “Question”,
“name”: “What is the Target Audience for the 950-STCL1?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “
The primary audience includes students in HVACR, renewable energy technology, and industrial maintenance programs. It is ideal for use at community colleges, vocational schools, and technical training centers preparing the next generation of technicians.
”
}
},
{
“@type”: “Question”,
“name”: “Does the system include fault insertion capabilities?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “
Yes, it includes a comprehensive fault insertion system. This allows instructors to introduce common real-world problems for students to diagnose in a controlled setting, such as sensor failures, pump malfunctions, and controller errors.
”
}
},
{
“@type”: “Question”,
“name”: “Is curriculum included with the trainer?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “
Yes, the 950-STCL1 system comes with a detailed student curriculum delivered in an interactive multimedia format. A comprehensive instructor’s guide is also included to facilitate lesson planning and hands-on lab exercises.
”
}
},
{
“@type”: “Question”,
“name”: “What utilities are required to operate the system?”,
“acceptedAnswer”: {
“@type”: “Answer”,
“text”: “
The system requires a standard 120VAC/60Hz electrical connection and a water supply for the heat exchanger loop. A heat source, such as the included solar collector lamp, is also necessary for full operational training.
”
}
}
]
}
For more information or to contact Aidex, your Authorized Reseller, call 800-251-9935 or email info@aidex.com.
If your wish list isn’t clear, your dreams won’t be either. When you model thoughtful planning for your CTE program, you’re teaching students how to turn their own dreams into reality.